Ironing Pattern Calibration

needs:Temperature
Flow

You need to do the filament flow calibration and the bridge flow ratio before this one. It's better if you have done the filament temperature.

This calibration method will print test samples with various levels of over-bridge flow ratio, between 100 and 125. Choose the lowest value on which the top surface is smooth without rough "holes". Began with the over-bridge calibraiton.

If the over-bridge calibration is not conclusive (same holes on all samples), then set it to 110% and use the top flow calibration. This setting is a bit more unpredictable so it's best to not move it far away from 100%.

Results

Exemple:

not flat not flat not flat flat Flat
Here, we can see that artifacts exist until the over-bridge flow was set to 115. It was flat from the flow calibration, if it's not now, it's because the bridges below the top surfaces are dropping a bit, and so it leaves more volume to fill afterwards. Here, 115 should be enough, but 120 is a more safe bet.

Advice

TODO

Notes

This test set the setting "complete individual objects" to true, so you may want to reset your print settings afterwards

Licence for models used for this calibration test: CC BY-SA 3.0